Base pan corrosion is what usually retires an older window unit. Condensate sits in the pan by design, and once the metal perforates the unit leaks into the room regardless of tilt.
Owners can inspect the pan when cleaning and check the tilt. Refrigeration and electrical repairs belong to a technician, but a perforated pan generally means replacement rather than repair.
Key Features
- Window room air conditioner of the ACE family
- Energy saver operation on equipped variants
- Multi-speed fan
- Washable filter
Most Common Issues on This Model
Evaporator icing in cool weather
Thermostat cycling too frequently
Louvre mechanism stiffening
Cabinet corrosion at the base pan