A dehumidifier whose fan runs but which collects no water has either lost refrigerant, has a failed compressor, or is being run in a room too cold for it. The last is free to rule out.
Owners can check the float moves freely and the filter is present and clean. Refrigeration diagnosis requires a technician, and on units of this age the repair cost is usually weighed against a replacement.
Key Features
- Portable dehumidifier of the AD family
- Removable collection bucket
- Mechanical humidistat
- Top-mounted controls
Most Common Issues on This Model
Bucket float switch sticking
Filter missing after cleaning
Fan running without dehumidifying
Cabinet vibration on a hard floor