Scale settles on the lower element, so it fails first in hard-water areas and the household then runs out of hot water faster than before while still getting hot water briefly.
Owners should not open the element panels. The circuit is high current and the tank is full of hot water – a technician isolates the breaker, drains as required and replaces the element and thermostat together.
Key Features
- Electric storage water heater
- Dual element design
- Serviceable thermostats behind access panels
- Glass-lined tank
Most Common Issues on This Model
Lower element scaling in hard water
Thermostat failing to cut out
Relief valve discharging
Insulation sagging around access panels