Manual-defrost uprights frost across the shelves because the evaporator coils run through them. That is normal, and the cabinet needs defrosting once the layer gets thick enough to affect airflow or block a basket.
Owners should never chip the frost off those shelves – the tubing is inside them and a puncture ends the freezer. Unplug it, empty it and let it thaw with the door open, using towels and bowls of warm water if needed.
Key Features
- Upright freezer of the EV family
- Manual defrost design
- Fixed wire shelving
- Mechanical control
Most Common Issues on This Model
Frost bridging the shelves so drawers will not move
Door seal flattening at the hinge side
Temperature control drifting over time
Compressor running hot in a confined space