Saddle valves fitted decades ago are a common restriction on older ice makers. They clog slowly, and the machine simply produces less ice each year until someone measures the flow.
Owners can check the supply valve is fully open and run cleaning cycles. Replacing a saddle valve with a proper shut-off is plumbing work worth doing when a technician is on site anyway.
Key Features
- 15-inch undercounter ice maker
- Black finish variant
- Front-vented cabinet
- Manual cleaning cycle
Most Common Issues on This Model
Scale building without regular cleaning
Bin door hinge wearing
Ice harvesting slowly in a hot room
Water line restricting at the saddle valve