With mechanical controls there is little to go wrong electronically on this cabinet, so a unit that will not restart after a power cut usually points at the start relay or the overload on the compressor rather than a control board.
A relay that has failed makes a distinctive click-and-hum cycle every few minutes. Owners should not attempt compressor electrical work: the components sit in the machine compartment and carry mains voltage. A technician can test the relay and the windings quickly.
Key Features
- Full-size top-freezer cabinet
- Mechanical temperature controls
- Adjustable door bins
- Biscuit and white finish variants
Most Common Issues on This Model
Cabinet not restarting after a power cut
Thermostat drifting so the fridge runs too cold
Freezer door hinge wearing
Drain pan overflowing at the back