Refrigerators from this generation are now well past their warranty, and their faults are predictable. The drain trough behind the rear fresh-food panel is the classic weak point: once ice bridges it, meltwater runs forward and collects under the crispers on every defrost cycle.
The other common call is a door that will not stay shut, which is usually worn closing cams at the hinge rather than a warped door. Owners can safely level the cabinet and check the seals; internal drain and defrost work is for a technician, with the power off first.
Key Features
- French door cabinet with a pull-out bottom freezer
- Internal water filter
- Humidity-controlled crispers
- White and stainless finish variants
Most Common Issues on This Model
Defrost drain freezing and sending water into the fridge floor
Ice maker stopping after a power interruption
Door closing cams wearing so the door drifts open
Evaporator fan noise that changes when a door is opened